Skip to content

Magnetic Autocontrol supplier, installation & repair in Ajman

Supplied, installed, serviced and repaired by Qasar Al Neil Automatic Doors.

Magnetic Autocontrol is a German manufacturer based in Schopfheim that makes vehicle and pedestrian access control equipment: automatic barriers, turnstiles, security gates and parking equipment. The company is part of the FAAC Group. We install, repair and maintain Magnetic Autocontrol barriers and gates for car parks, compounds, factories and commercial buildings in Ajman and across Ajman.

Magnetic Autocontrol boom barrier repair in Ajman

A car park barrier opens and closes many times a day, so wear shows up in predictable places. We find the cause before replacing anything.

  • Arm will not lift or lower: a failed control board, a worn motor, a loose crank or a limit switch out of position.
  • Arm bounces or hits the post: balancing springs that have lost tension or a damaged arm mounting.
  • Barrier opens and closes by itself: a faulty loop detector, a loose loop wire or a bad connection to the controller.
  • Barrier stays open: a blocked safety photocell or a loop that still senses a vehicle.

Our boom barriers service describes what we cover.

Magnetic Autocontrol turnstiles and pedestrian gates

Magnetic Autocontrol also builds turnstiles, e-gates and full-height turnstiles for lobbies, plants and staff entrances. Faults we meet include arms that do not release after a valid card, lane sensors that stay blocked, worn bearings and control boards that lose communication with the reader. We test the release signal, mechanism and sensors, and check the emergency release. See turnstiles and speed gates.

Barriers often sit inside a parking system with tickets, ANPR cameras or card readers. When a barrier does not respond, the fault can be in the barrier, the cable or the reader or ticket unit that triggers it. We test each stage so the cause is isolated. Related work is described under parking management systems.

Magnetic Autocontrol installation and maintenance

New work starts with the lane layout: barrier position, arm length, loop positions, safety sensors and power supply. After installation we set the arm travel, test the loops and photocells, and run the barrier through repeated cycles. A maintenance visit covers:

  • Checking arm, springs, pivots and fixings for wear.
  • Testing limit positions and obstruction response.
  • Inspecting loop wiring and detector settings.
  • Cleaning and testing photocells.
  • Checking cabinet seals, wiring and power supply.

Qasar Al Neil Automatic Doors installs, repairs and maintains Magnetic Autocontrol equipment. We also look after Automatic Systems turnstiles and barriers. Ask for a free site visit to have your lanes inspected.

How to choose Magnetic Autocontrol barrier service

Before a visit, collect a few facts about the Magnetic Autocontrol equipment. They let the technician bring the right tools and likely parts, and they shorten the time on site. The table lists what helps most.

ItemWhat to noteWhy it matters
EquipmentTerminal, reader, controller, lane or gateShows what needs testing
Users and softwareNumber of users, software usedAffects settings and data export
Door or lane linkLock type, release, fire inputThe signal path decides if a door opens
Network and powerCable type, switch, supplyOffline terminals often trace to these

Magnetic Autocontrol in UAE conditions

Access control hardware in the UAE faces 45 to 50 C heat at outdoor lanes, dust, humidity and supply dips. Readers and sensors near entrances need clean lenses and sealed cable entries. Controllers should sit on a stable supply, ideally with a small backup, so a power dip does not drop doors or lanes.

Magnetic Autocontrol spare parts and older units

We check whether a part for your Magnetic Autocontrol unit can be sourced before quoting. Where the original part is no longer available, we say so and suggest a compatible replacement, and we do not promise a part until we have seen the unit. Photos of the label and the fault help, and you can send them through send a photo.

To plan the work, ask for a free site visit or request a quote. Related questions: Why does my barrier arm bounce or drift when it stops? and Why will my Magnetic Autocontrol barrier arm not lift?.

Magnetic Autocontrol in Ajman

Magnetic Autocontrol owners in Ajman can book Qasar Al Neil Automatic Doors for survey, installation, programming and repair. Localities with their own pages on this site include Al Nuaimiya, Al Rashidiya, Al Rawda, Al Hamidiya, Al Jurf and Al Jurf Industrial Area.

In Ajman, Magnetic Autocontrol appears on this site under parking management systems, turnstiles & speed gates and boom barriers & parking barriers. Industrial and free-zone sites such as Al Jurf Industrial Area, Ajman Free Zone and Ajman Industrial Area usually ask about heavier duty equipment, so tell us how often the opening is used.

No project page for Ajman names Magnetic Autocontrol yet. Send us the model and a photo of your Magnetic Autocontrol unit and we plan the visit around it.

Do you service Magnetic Autocontrol in Al Nuaimiya and Al Rashidiya?
Yes. Qasar Al Neil Automatic Doors attends Magnetic Autocontrol systems in Al Nuaimiya, Al Rashidiya and other localities of Ajman. Give us the address and the model and we book a free site visit.
Which Magnetic Autocontrol products can I ask about in Ajman?
In Ajman, Magnetic Autocontrol appears under parking management systems, turnstiles & speed gates and boom barriers & parking barriers. Tell us what you need and we confirm the options at the free site visit.

Magnetic Autocontrol services we offer

  • Parking Management Systems

    Parking Management Systems

    Automate ticketing, payment, access and space counting so your car park runs itself and revenue is never lost.

    Explore
  • Turnstiles & Speed Gates - automatic doors & gates by Qasar Al Neil Automatic Doors

    Turnstiles & Speed Gates

    Control pedestrian flow at entrances with tripod, flap and swing turnstiles integrated with your access control.

    Explore

We install & repair magnetic autocontrol systems

Free site survey, installation, repair and maintenance across Ajman.

Supply & installation

Survey, supply, fitting, wiring, programming and safety testing.

Installation details →

Repair & maintenance

Fault-finding for motors, boards, remotes, sensors and safety edges.

Repair details →

Parts we repair & replace:

  • Boom Barrier & Boom Arm
  • Barrier Motor / Gearbox
  • Loop Detector
  • Control Board (PCB)
  • Ticket Dispenser / Validator
  • ANPR / LPR Camera
  • Pay Station Module
  • RFID / Long-range Reader
  • Photocell Safety Sensor
  • Parking Guidance Sensor
  • UPS / Backup Battery

Magnetic Autocontrol service across Ajman

Magnetic Autocontrol service, frequently asked questions

Why will my Magnetic Autocontrol barrier arm not lift?

An arm that stays down can have a power fault, a failed control board, a motor problem or a limit switch that is out of position. A loop detector or safety input that is still reading as occupied can also hold the arm. We check power first, then the board indicators, the loop and photocell signals and the mechanism. If the arm is jammed by a bent mounting or a stiff pivot, we free it and inspect the springs.

What should I do if a Magnetic Autocontrol barrier closes on vehicles?

Stop using the lane and call a technician. A barrier that closes on a vehicle usually has a faulty or misaligned safety device, such as a photocell or loop detector, or a loop that has failed. We test the loop and photocell, check the detector settings and confirm that the barrier reverses on obstruction. Do not bypass safety devices to keep the lane running, because that exposes vehicles and people to risk.

Why does a Magnetic Autocontrol turnstile not release for valid users?

If the reader accepts a card but the arms stay locked, the cause is often the release signal between reader and turnstile, a faulty control board or a blocked lane sensor. Bent arms, worn bearings and debris in the mechanism can also stop movement. We check the signal, test the board and sensors, and inspect the mechanism. The emergency release is tested before we finish.

Why does my barrier arm bounce or drift when it stops?

Bouncing or drifting usually means the balance is wrong. Springs lose tension over many cycles, an arm may have been changed to a different length, or a fitting such as a light strip or skirt adds weight. Worn pivots also contribute. We check the spring tension, the arm weight and the mounting, then readjust the balance and travel. A badly balanced arm strains the motor and gearbox, so it is worth fixing early.

What should I prepare before a Magnetic Autocontrol barrier maintenance visit?

Tell us which lanes have problems and when they appear, for example only in heavy traffic or after rain. Arrange a time when a lane can be closed briefly, and let security staff know. Have access to the controller cabinet and any ticket or reader units on the lane. If you have the model plate details of the barrier, note them down so we can check the setup before arrival.

What is the difference between a boom barrier and a swing gate for a car park entrance?

A boom barrier is a long arm that rises vertically, controlling vehicle access without physically blocking the full width of the road when open, so it opens and closes in one to three seconds and handles high vehicle throughput well. A swing gate is a full panel that blocks the entire opening, giving more physical security but taking longer to cycle and needing more clearance space.

For a car park or compound with steady vehicle flow, a boom barrier paired with a loop detector and access control card reader is the standard setup. A swing or sliding gate makes more sense where you need a solid physical barrier after hours, not just traffic control.

How fast does an automatic boom barrier open and close?

Most boom barriers open in around 1 to 3 seconds, depending on the arm length and whether it is set for standard or fast operation. Faster cycling models exist for high-traffic entrances like paid parking exits or logistics yards where queue length matters, though very fast cycling increases wear on the motor and gearbox over time.

We set barrier speed based on your traffic volume at survey, balancing throughput against component longevity rather than defaulting to the fastest setting for every site.

Do parking barriers work during a power outage?

Standard barriers stop in the down or up position depending on where they were when power was lost, and most have a manual release lever that lets security staff physically lift the arm to let vehicles through. A backup battery is available as an add-on that keeps the barrier operating automatically for a limited time during an outage.

For sites where an obstructed exit during a power cut is a real safety concern, like a busy car park, we recommend the manual release be tested regularly as part of routine maintenance, not just installed and forgotten.

Other brands we work on

Need a door or gate fixed in Ajman? Book a free site visit